20100128 15:09:40.186 = PROCCESSING: Linearity Test: --------------------------------------------------------------------------------------| 20100128 15:09:40.186 = PROCCESSING: Linearity Test: *****DEVICE SETTINGS ***** 20100128 15:09:40.186 = PROCCESSING: Linearity Test: Device Resolution = 0.00125 cm 20100128 15:09:40.186 = PROCCESSING: Linearity Test: Sampling Rate = 100 Hz 20100128 15:09:40.186 = PROCCESSING: Linearity Test: Minimum Pen Pressure = 1 20100128 15:09:40.202 = PROCCESSING: Linearity Test: --------------------------------------------------------------------------------------| 20100128 15:09:40.202 = PROCCESSING: Linearity Test: Reading hwrfile C:\Documents and Settings\All Users\Documents\NeuroScript\TTT\IT3\6X8\GRP\IT36X8GRPSSL05.HWR. 20100128 15:09:40.217 = PROCCESSING: Linearity Test: ***** SAMPLES ***** 20100128 15:09:40.217 = PROCCESSING: Linearity Test: # Input Samples = 80 20100128 15:09:40.217 = PROCCESSING: Linearity Test: # Samples after trailing penlift removed = 71 20100128 15:09:40.217 = PROCCESSING: Linearity Test: # Samples of Pendown = 71 = 0.71 s 20100128 15:09:40.217 = PROCCESSING: Linearity Test: First Sample coordinates = (6437, 3827, 50). 20100128 15:09:40.217 = PROCCESSING: Linearity Test: Last Sample Coordinates = (34677, 24415, 66). 20100128 15:09:40.217 = PROCCESSING: Linearity Test: Xlength = 28240 units = 35.30 cm, Ylength = 20588 units = 25.73 cm, Absolute length = 34948 units =43.69 cm. 20100128 15:09:40.217 = PROCCESSING: Linearity Test: Average velocity = 499 units/sample = 62.4 cm/s. 20100128 15:09:40.217 = PROCCESSING: Linearity Test: Movement begins at begin of first 3 points with velocity greater than (1.33*Avg Vel) of entire movement. 20100128 15:09:40.217 = PROCCESSING: Linearity Test: Movement ends at begin of first 3 points with velocity lesser than (1.33*Avg Vel) of entire movement. 20100128 15:09:40.217 = PROCCESSING: Linearity Test: Segment 0: Samples 17 to 36. Estimated range of movement = 20 samples. 20100128 15:09:40.217 = PROCCESSING: Linearity Test: Straight line fitted (r=1.000) y = -941.163 + 0.731 * x. 20100128 15:09:40.233 = PROCCESSING: Linearity Test: --------------------------------------------------------------------------------------| 20100128 15:09:40.233 = PROCCESSING: Linearity Test: | ***** SPATIAL ERROR (Accuracy of the device)***** 20100128 15:09:40.233 = PROCCESSING: Linearity Test: | RMS coordinate error = 3.88 units = 0.00485 cm. 20100128 15:09:40.233 = PROCCESSING: Linearity Test: --------------------------------------------------------------------------------------| 20100128 15:09:40.233 = PROCCESSING: Linearity Test: RMS quantization error due to the device resolution = 0.289 units = 0.000361 cm. 20100128 15:09:40.233 = PROCCESSING: Linearity Test: RMS spatial error relative to quantization error = 13.4 20100128 15:09:40.233 = PROCCESSING: Linearity Test: RMS coordinate error without quantization error = 3.87 units = 0.00484 cm. 20100128 15:09:40.233 = PROCCESSING: Linearity Test: (If RMS coordinate error without quantization error approaches the spatial error, a better device resolution will not improve accuracy). 20100128 15:09:40.233 = PROCCESSING: Linearity Test: Length of fitted line = 1327 units = 1.66 cm; Straightness Error = 0.00293. 20100128 15:09:40.233 = PROCCESSING: Linearity Test: Rotated counterclock (rad)= 0.94 = 108 degree. 20100128 15:09:40.233 = PROCCESSING: Linearity Test: Writing hwrfile C:\Documents and Settings\All Users\Documents\NeuroScript\TTT\IT3\6X8\GRP\IT36X8GRPSSL05.unr (ns = 71). 20100128 15:09:40.233 = PROCCESSING: Linearity Test: Differentiate y into z. 20100128 15:09:40.233 = PROCCESSING: Linearity Test: Set z[i] = y[i+1]-y[i] (z = differences between successive samples) 20100128 15:09:40.233 = PROCCESSING: Linearity Test: Set y[i] = (y[i+1] - y[i])/RunningAverage(y[i] - y[i-1]). (y = #Missing Samples+1 or 1/(#Extra Samples+1)) 20100128 15:09:40.248 = PROCCESSING: Linearity Test: Average velocity of the fitted line= 821 units/sample = 8.29 cm/s. 20100128 15:09:40.248 = PROCCESSING: Linearity Test: --------------------------------------------------------------------------------------| 20100128 15:09:40.248 = PROCCESSING: Linearity Test: | ***** TEMPORAL ERROR (Equidistant sampling measure, missing samples, extra samples)***** 20100128 15:09:40.248 = PROCCESSING: Linearity Test: --------------------------------------------------------------------------------------| 20100128 15:09:40.248 = PROCCESSING: Linearity Test: | # Samples above average velocity to be used in the linearity test = 20 20100128 15:09:40.248 = PROCCESSING: Linearity Test: | # Cases of 1 Samples Missing = 1 20100128 15:09:40.248 = PROCCESSING: Linearity Test: | # Cases of 2 Samples Missing = 1 20100128 15:09:40.248 = PROCCESSING: Linearity Test: | # Cases of >=3 Samples Missing = 0 20100128 15:09:40.248 = PROCCESSING: Linearity Test: | Total # Samples Missing = 3 = 15.0% 20100128 15:09:40.264 = PROCCESSING: Linearity Test: | # Cases of 1 Samples Extra = 0 20100128 15:09:40.264 = PROCCESSING: Linearity Test: | # Cases of 2 Samples Extra = 0 20100128 15:09:40.264 = PROCCESSING: Linearity Test: | # Cases of >=3 Samples Extra = 0 20100128 15:09:40.264 = PROCCESSING: Linearity Test: | Total # Samples Extra = 0 = 0.0% 20100128 15:09:40.264 = PROCCESSING: Linearity Test: --------------------------------------------------------------------------------------| 20100128 15:09:40.280 = USER INTERFACE: Charting C:\Documents and Settings\All Users\Documents\NeuroScript\TTT\IT3\6X8\GRP\IT36X8GRPSSL05.HWR. 20100128 15:12:55.160 = USER INTERFACE: NOTEPAD C:\Documents and Settings\All Users\Documents\NeuroScript\TTT\\Actions.log