Accuracy Test Results - AIPTEK T-12000U 9x12 - Grip Pen
Driver: |
Version 4.96-7 |
Software: |
Movalyzer® 4.0 |
Computer: |
Pentium4 CPU, 3.00 GHz, 512 MB RAM, no other applications are running. |
O/S: |
Windows XP Professional 2002, SP2 |
Date: |
12 Dec 2006 |
ACCURACY: |
± 0.017 cm |
Want to know how we obtained these results?
Acquired Resolution (cm) |
Acquired Sampling Rate (Hz) |
Measured RMS coord. error (cm/units) |
Measured Missing/Extra Samples (%) |
.00125 |
100 |
0.017 / 3.37 |
0% / 0% |
STRAIGHTNESS AND SMOOTHNESS GRAPH |
PRESSURE MEASUREMENT GRAPH |
ACCELERATION SPECTRUM GRAPH |
MISSING/EXTRA SAMPLE ESTIMATOR |
PEN PRESSURE MEASUREMENT DATA |
OBJECT
|
WEIGHT (g)
|
z Output Units
|
Units/Weight (1/g)
|
None
|
0
|
0
|
|
Pen |
21 |
0
|
21 |
Pen+Vertical stand
|
87 |
0 |
87 |
Pen+Vertical stand + 100 g
|
178
|
230 |
178 |
Pen+Vertical stand + 200 g
|
278
|
380 |
278 |
Min. weight for max. pressure
|
387 |
490 |
387 |
STRAIGHTNESS AND SMOOTHNESS GRAPH |
ACCELERATION SPECTRUM GRAPH |
MISSING/EXTRA SAMPLE ESTIMATOR |